CALCulate Subsystem 3
Keysight N8262A Programming Guide 199
Example
Reset Condition
On reset, both windows and their measurements are set to ON.
Query
CALCulate[1]|2|3|4:LIMit:CLEar:AUTO?
The query command enters a 1 or 0 into the output buffer indicating whether limit
failures are cleared automatically when a new measurement is initiated on the
specified window section.
– 1 is entered into the output buffer when limit failures are cleared automatically
when a new measurement is initiated.
– 0 is entered into the output buffer when limit failures are not cleared
automatically when a new measurement is initiated.
In the case where limit failures are cleared once, when a query occurs a 1 is
entered into the output buffer if no measurement is initiated. If a measurement is
initiated then 0 is entered.
Query Example
CALC1:LIM:CLE:AUTO 1 This command switches on automatic
clearing of the FCO for the upper window/
upper measurement.
CALC1:LIM:CLE:AUTO? This command queries when the FCO is
cleared for the upper window/upper
measurement.

Table of Contents

Other manuals for Keysight Technologies P Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies P Series and is the answer not in the manual?

Keysight Technologies P Series Specifications

General IconGeneral
BrandKeysight Technologies
ModelP Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals