4 CALibration Subsystem
236 Keysight N8262A Programming Guide
Query
CALibration[1]|2:RCFactor? [MIN|MAX]
The query returns the current setting of the reference calibration factor or the
values associated with MIN and MAX.
Query Example
Error Messages
If this command is used when a P-Series or E-Series power sensor is connected
the error –241, “Hardware missing” occurs.
CAL2:RCF? This command queries the reference
calibration factor of Channel B.