MEMory Subsystem 7
Keysight N8262A Programming Guide 307
Example
Query
MEMory:TABLe:FREQuency?
The query returns a list of frequency points for the table currently selected. The
frequencies are returned in Hz.
Query Example
Error Messages
– If more than 80 frequencies are in the list, error –108, “Parameter not allowed”
occurs.
– If the frequencies are not entered in ascending order, error –220, “Parameter
error;Frequency list must be in ascending order” occurs.
– If a table has not been specified using the MEMory:TABLe:SELect command,
the data cannot be entered into the table and error –221, “Settings conflict”
occurs.
– If a frequency is sent which is outside of the allowed frequency range, error
–222, “Data out of range” occurs.
MEM:TABL:FREQ 200kHz,600kHz This command enters frequencies of 200 kHz
and 600 kHz into the currently selected
table.
MEM:TABL:FREQ? This command queries the frequency points
in the currently selected table.