SYSTem Subsystem 12
Keysight N8262A Programming Guide 529
Trigger setup
TRIG[:SEQ[1]|2]:SOUR INT1
Trigger source set up and acquisition
mode continuous triggering
INIT:CONT ON
TRIG[:SEQ]:LEV:AUTO OFF
Disable automatic setting of the trigger
level
TRIG[:SEQ]:LEV -15 dBm Automatic Power level
TRIG[:SEQ]:SLOP POS
Trigger event recognized on the rising
edge of a signal
TRIG[:SEQ]:DEL 0 s
Delay between recognition of trigger event
and start of a measurement
TRIG[:SEQ]:HOLD 20 ms Trigger holdoff
Range
[a]
[SENS[1]]|SENS2:POW:AC:RANG:AUTO OFF Auto range off
[SENS[1]]|SENS2:POW:AC:RANG UPPER Range set to upper
Averaging
[SENSe[1]]|SENSe2:AVER[:STATe] ON Averaging On
[SENSe[1]]|SENSe2:AVER:COUN 64 Averaging set to 64
Step detection
[SENSe[1]]|SENS2:AVER:SDET 1 Step detection enabled
Trace setup
SENSe[1]|2:TRAC:LIM:UPP +20 dBm Maximum power
SENSe[1]|2:TRAC:LIM:LOW -30 dBm Minimum power
[SENS[1]]|SENS2:TRAC:OFFS:TIME
<numeric_value>
0 s
Delay between delayed trigger point and
the start of the trace
[SENS[1]]|SENS2:TRAC:TIME
<numeric_value>
100 ms Length of the trace
Table 12-44 iDEN: Power meter presets (continued)