EasyManuals Logo

Keysight Technologies P Series User Manual

Keysight Technologies P Series
673 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #434 background imageLoading...
Page #434 background image
11 STATus Subsystem
434 Keysight N8262A Programming Guide
STATus:OPERation:SENSe[:SUMMary]
The operation status sense summary register set contains information on the
status of the power sensors.
The following bits in these registers are used by the power meter:
These bits are set when the power meter is reading data from the E-Series power
sensor EEPROM.
These bits are cleared when the power meter is not reading data from the E-Series
power sensor EEPROM.
Syntax
Bit Number Decimal Weight Definition
0-Not used
1 2 Channel A SENSe Status
2 4 Channel B SENSe Status
3-15 - Not used
STAT
:OPER
:SENS
:SUMM