SYSTem Subsystem 12
Keysight N8262A Programming Guide 491
CDMA2000
The cdma2000 set-up provides:
– Average power in a cdma2000 signal (bandwidth <=5 MHz).
– Peak power and peak-to-average ratio of the signal over a defined, statistically
valid number of samples. The reading is continuously refreshed. This indicates
how cdma2000 channel loading affects peak power and power distribution.
The measurement is a continuously gated measurement on a 3 GPP cdma2000
signal. Its aim is to measure the peak and average power corresponding to a <0.01 %
probability that there are no peaks above the returned peak reading. Time gating is set
to 10 ms, corresponding to 200,000 samples. Triggering is set to occur continuously
internally to the meter. The internal trigger is set to AutoLevel. A reading over the 10
ms period is returned, then the reading is re-initiated for the next 10ms period. In this
way the reading always relates to a position beyond 0.01 % on the CCDF and will
refresh to track any signal or DUT changes.
The following table shows the power meter presets when <character_data> is
set to CDMA2000. Commands not listed are preset according to their DEFault
values (for further information refer to Table 12-1):
Table 12-11 cdma2000: Power meter presets
Command Setting Comments
Frequency
[SENS[1]]|SENS2:FREQ[:CW|:FIX] +1900.000 MHz Frequency setting
Sensor measurement mode
[SENS[1]]|SENS2:DET:FUNC NORM Measurement mode
Sensor video bandwidth setup
[SENS[1]]|SENS2:BAND|BWID:VID N1921/2A: OFF Sensor video bandwidth
Gate Setup
[SENS[1]]|SENS2:SWE[1]|2|3|4:OFF:TIME Gate 1: 0 s
Gates 2 - 4: 0
Delay between trigger point and time
gated period.
[SENS[1]]|SENS2:SWE[1]|2|3|4:TIME Gate 1: 10 ms
Gates 2 - 4: 0
Length of time gated period for time gated
measurements.
Trigger setup

Table of Contents

Other manuals for Keysight Technologies P Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies P Series and is the answer not in the manual?

Keysight Technologies P Series Specifications

General IconGeneral
BrandKeysight Technologies
ModelP Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals