15 UNIT Subsystem
608 Keysight N8262A Programming Guide
Parameters
Example
Reset Condition
On reset, all windows/measurements are set to DBM.
Query
UNIT[1]|2|3|4:POWer?
The query returns the current setting of the power measurement units.
Query Example
Item Description/Default Range of Values
amplitude_unit The measurement unit.
– The default unit is dBm
W
DBM
UNIT1:POW DBM This command sets the power measurement
units for the upper window/upper
measurement.
UNIT2:POW? This command queries which measurement
units are being used on the lower window/
upper measurement.