FQ2-S/CH User’s Manual
Inspection
Settings
Verification*
4
(Bar code*
3
, 2D-code*
3
, 2D-code (DPM)*
3
)
Verif. master
data
Sets whether to verify the read charac-
ter string against a character string
that is registered in the master data.
Sets the character string to use to ver-
ify the read character string against
the master data.
OFF
All master data (Default)
Master data 0 to 31 Scene
p. 182
p. 194
p. 207
Master data reg-
ist. Registers a character string in the
master data.
Master data 0 to 31 Scene
[MENU]
Auto
Reads a character string from an input
image and registers it in the master
data.
--- Scene
Insp.
region
Manual
L.1 to
L.4
Registers a character string directly in
the master data.
32 alphanumeric characters Scene
Item ref.
Ref.
data
Registers the immediately preceding
read results as a verification character
string.
--- Scene
Line 1
verif.
range to
Line 4
verif.
range
Sets the beginning and end characters
to verify for each line.
1 to 1024
(Defaults: beginning: 1
       end: 1024)
Scene
Copy
Copies or clears registered master
data.
--- ---
Delete
Details
(OCR*
4
)
Meas. Parameter Same as [Teach] [Meas. Parameter]
under [Modify] or [Inspection].
Scene p. 156
Dictionary param. Sets the model dictionary to register
custom characters.
--- Scene
p. 169
Dictionary ref. Sets the dictionary data to use for
character recognition.
None (Default)
Dictionary data 0 to 31
Scene
Individual char.
When you have number, alphabet, or
symbol that want to exclude, touch
Individual char, and then unchecked
the attempt character,
---
Scene
Number 0 to 9
Alphabet A to Z
Symbol
: (colon)
/ (slash)
() (parentheses)
Date Parameters
Period Setting
Year
Set the period setting of the current
date and time.
0 to 99 (Default: 0) Scene
Month 0 to 99 (Default: 0)
Day -999 to 999 (Default: 0)
Menu command Description Setting range Data