SP3-XXX (Process)
D0CA/D0C9/D0C8/D0CB 3-174 SM Appendices
SP No. Large Category Small Category ENG
or
CTL
[Min to
Max/Init./Step]
1point/step]
3-627-01
2
ID Pattern Extraction:
Set
Edge Upper Limit: Std Speed
2
ENG
*
[0 to 255 / 22 /
1point/step]
3-627-02
1
ID Pattern Extraction:
Set
Edge Lower Limit ENG
*
IM C300 series: [0 to
255 / 14 /
1point/step]
IM C400 series: [0 to
255 / 10 /
1point/step]
3-627-02
2
ID Pattern Extraction:
Set
Edge Lower Limit: Std Speed
2
ENG
*
[0 to 255 / 9 /
1point/step]
3-627-03
1
ID Pattern Extraction:
Set
Vsg Upper Threshold ENG
*
[0.000 to 5.000 /
4.800 / 0.001V/step]
3-627-04
1
ID Pattern Extraction:
Set
Vsg Lower Threshold ENG
*
[0.000 to 5.000 /
3.000 / 0.001V/step]
3-628-00
1
ID Pattern Timing: Set Scan: YMCK ENG
*
[-500.0 to 500.0 / 0.0
/ 0.1mm/step]
3-628-00
2
ID Pattern Timing: Set Detection Delay Time ENG
*
[0 to 2500 / 0 /
1msec/step]
3-628-00
3
ID Pattern Timing: Set Delay Time ENG
*
IM C300 series: [0 to
2500 / 701 /
1msec/step]
IM C400 series: [0 to
2500 / 592 /
1msec/step]
3-628-00
4
ID Pattern Timing: Set MUSIC Delay Time ENG
*
[-2500 to 2500 / 150 /
1msec/step]
3-628-00
5
ID Pattern Timing: Set Delay Time: Std Speed 2 ENG
*
[0 to 2500 / 569 /
1msec/step]
3-630-00
1
Dev gamma: Disp/Set Current:Bk ENG
*
[0.10 to 6.00 / 0.80 /
0.01mg/cm2/-kV/step
]
3-630-00
2
Dev gamma: Disp/Set Current:C ENG
*
[0.10 to 6.00 / 0.75 /
0.01mg/cm2/-kV/step
]
3-630-00 Dev gamma: Disp/Set Current:M ENG [0.10 to 6.00 / 0.75 /