SP3-XXX (Process)
SM Appendices
3-175 D0CA/D0C9/D0C8/D0CB
SP Mode Tables
SP No. Large Category Small Category ENG
or
CTL
[Min to
Max/Init./Step]
3 * 0.01mg/cm2/-kV/step
]
3-630-00
4
Dev gamma: Disp/Set Current:Y ENG
*
[0.10 to 6.00 / 0.75 /
0.01mg/cm2/-kV/step
]
3-630-01
1
Dev gamma: Disp/Set Target:Bk ENG
*
[0.50 to 2.55 / 0.80 /
0.01mg/cm2/-kV/step
]
3-630-01
2
Dev gamma: Disp/Set Target:C ENG
*
[0.50 to 2.55 / 0.75 /
0.01mg/cm2/-kV/step
]
3-630-01
3
Dev gamma: Disp/Set Target:M ENG
*
[0.50 to 2.55 / 0.75 /
0.01mg/cm2/-kV/step
]
3-630-01
4
Dev gamma: Disp/Set Target:Y ENG
*
[0.50 to 2.55 / 0.75 /
0.01mg/cm2/-kV/step
]
3-630-06
1
Dev gamma: Disp/Set Toner Density: Bk ENG
*
[0.0 to 25.5 / 0.0 /
0.1wt%/step]
3-630-06
2
Dev gamma: Disp/Set Toner Density: C ENG
*
[0.0 to 25.5 / 0.0 /
0.1wt%/step]
3-630-06
3
Dev gamma: Disp/Set Toner Density: M ENG
*
[0.0 to 25.5 / 0.0 /
0.1wt%/step]
3-630-06
4
Dev gamma: Disp/Set Toner Density: Y ENG
*
[0.0 to 25.5 / 0.0 /
0.1wt%/step]
3-631-00
1
Development Start
Vk :Display
Bk ENG
*
[-300 to 300 / 0 /
1-V/step]
3-631-00
2
Development Start
Vk :Display
C ENG
*
[-300 to 300 / 0 /
1-V/step]
3-631-00
3
Development Start
Vk :Display
M ENG
*
[-300 to 300 / 0 /
1-V/step]
3-631-00
4
Development Start
Vk :Display
Y ENG
*
[-300 to 300 / 0 /
1-V/step]
3-700-00
1
New Unit Detection ON/OFF Setting ENG
*
[0 to 1 / 1 / 1/step]
3-701-00 Manual New Unit Set # PCU:Bk ENG [0 to 1 / 0 / 1/step]