Error Codes
SM 27 D0CK
Code Meaning Suggested Cause/Action
substitute RX or confidential RX
message
Ask the other end to resend the message.
5-25 SAF file access error
Replace an SD card or HDD.
Replace the FCU (PCB2).
6-00 G3 ECM - T1 time out during
reception of facsimile data
Try adjusting the RX cable equalizer.
Replace the FCU (PCB2).
6-01 G3 ECM - no V.21 signal was
received
6-02 G3 ECM - EOR was received
6-04 G3 ECM - RTC not detected
Check the line connection.
Check for a bad line or defective remote
terminal.
Replace the FCU (PCB2).
6-05 G3 ECM - facsimile data frame not
received within 18s of CFR, but there
was no line fail
Check the line connection.
Check for a bad line or defective remote
terminal.
Replace the FCU (PCB2).
Try adjusting the RX cable equalizer
Cross reference
RX cable equalizer - G3 Switch 07 (PSTN)
6-06 G3 ECM - coding/decoding error
Defective FCU (PCB2).
The other terminal may be defective.
6-08 G3 ECM - PIP/PIN received in reply to
PPS.NULL
The other end pressed Stop during
communication.
The other terminal may be defective.
6-09 G3 ECM - ERR received
Check for a noisy line.
Adjust the TX levels of the communicating
machines.
See code 6-05.
6-10 G3 ECM - error frames still received
at the other end after all
communication attempts at 2400 bps
Check for line noise.
Adjust the TX level (use NCU parameter 01 or
the dedicated TX parameter for that address).
Check the line connection.
Defective remote terminal.
6-21 V.21 flag detected during high speed
modem communication
The other terminal may be defective or
incompatible.
6-22 The machine resets the sequence
Check for line noise.