Bit Switches – 3
SM 81 D0CK
Communication Switch 10 (SP No. 1-104-017)
No Function Comments
0-
7
Memory transmission: Maximum number of dialing attempts to the same
destination
01 – FE (Hex)
times
Communication Switch 11 – Not used (do not change the settings.)
Communication Switch 12 (SP No. 1-104-019)
No Function Comments
0-
7
Memory transmission: Interval between dialing attempts to the same
destination
01 – FF (Hex)
minutes
Communication Switch 13 – Not used (do not change the settings.)
Communication Switch 14 (SP No. 1-104-021)
No Function Comments
0 Inch-to-mm conversion during
transmission
0: Disabled, 1: Enabled
0: In immediate transmission, data scanned in inch format are
transmitted without conversion.
In memory transmission, data stored in the SAF memory in
mm format are transmitted without conversion.
Note: When storing the scanned data into SAF memory, the
fax unit always converts the data into mm format.
1: The machine converts the scanned data or stored data in
the SAF memory to the format which was specified in the set-
up protocol (DIS/NSF) before transmission.
1-
5
Not used Do not change the factory settings.
6-
7
Available unit of resolution in
which fax messages are
received
For the best performance, do not change the factory settings.
The setting determined by these bits is informed to the
transmitting terminal in the pre-message protocol exchange (in
the DIS/NSF frames).
Bit 7 Bit 6 Unit
0 0 mm
0 1 inch
1 0 mm and inch
1 1 Not used
Communication Switch 15 – Not used (do not change the settings)