Bit Switches – 3
D0CK 82 SM
Communication Switch 17 (SP No. 1-104-024)
No Function Comments
0 SEP reception
0: Disabled
1: Enabled
0: Polling transmission to another maker's machine using
the SEP (Selective Polling) signal is disabled.
1 SUB reception
0: Disabled
1: Enabled
0: Confidential reception to another maker's machine using
the SUB (Sub-address) signal is disabled.
2 PWD reception
0: Disabled
1: Enabled
0: Disables features that require PWD (Password) signal
reception.
3-
4
Not used Do not change the settings.
5 PSTN dial-in routing setting
0: OFF
1: ON
1: The machine sets multiple PSTN dial-in numbers in the
PSTN dial-in line and transfers received data from each
PSTN dial-in number to each address.
6 Not used Do not change the settings.
7 Action when there is no box with
an F-code that matches the
received SUB code
0: Disconnect the line
1: Receive the message
(using normal reception mode)
Change this setting when the customer requires.
Communication Switch 18 (SP No. 1-104-025)
No Function Comments
0-4 Not used Do not change the settings.
5 IP-Fax dial-in routing selection
0: Off
1: On
1: Transfers received data to each IP-Fax dial-in number.
IP-Fax dial-in number is a 4-digit number.
6-7 Not used Do not change the settings.
Communication Switch 19 - Not used (do not change the settings)
Communication Switch 1A - Not used (do not change the settings)
Communication Switch 1B (SP No. 1-104-028)
No Function Comments