Bit Switches – 3
SM 83 D0CK
0-
7
Extension access code
(0 to 7) to turn V.8
protocol On/Off
0: On
1: Off
If the PABX does not support V.8/V.34 protocol procedure, set this bit
to "1" to disable V.8.
Example: If "0" is the PSTN access code, set bit 0 to 1. When the
machine detects "0" as the first dialed number, it automatically
disables V.8 protocol. (Alternatively, if "3" is the PSTN access code,
set bit 3 to 1.)
Communication Switch 1C (SP No. 1-104-029)
No Function Comments
0-
1
Extension access code
(8 and 9) to turn V.8
protocol On/Off
0: On
1: Off
Refer to communication switch 1B.
Example: If "8" is the PSTN access code, set bit 0 to 1. When the
machine detects "8" as the first dialed number, it automatically
disables V.8 protocol. (If "9" is the PSTN access code, use bit 1.)
2-
7
Not used Do not change the settings.
Communication Switch 1D - Not used (do not change the settings)
Communication Switch 1E - Not used (do not change the settings)
Communication Switch 1F - Not used (do not change the settings)