12. Turn the power ON.
• After turning ON the main power, SC870 will occur and the address book data will
be cleared.
• SC673 appears at start-up, but this is normal behavior. This is because the
controller and the smart operation panel cannot communicate with each other due
to changing the SP settings for the operation panel.
13. Change the SP settings for the operation panel.
If you switch the screen to enter the SP mode, SC995-02 is displayed. However, continue
the following steps.
• SP5-748-101: (OpePanel Setting: Op Type Action Setting): Change bit 0 from 0 to 1.
• SP5-748-201: (OpePanel Setting: Cheetah Panel Connect Setting): Change the value
from 0 to 1.
14. Change the Flair API SP values.
• SP5-752-001 (Copy FlairAPIFunction Setting): Change bit 0 from 0 to 1.
• SP3-301-001 (FAX:FlairAPI Setting) Change bit 0 from 0 to 1.(You can NOT change
this Values if the FCU is not equipped with main machine )
15. Cycle the main power OFF/ON with the SD card where the NVRAM data has been
uploaded in SD slot 2.
• The model information is written on the NVRAM (Novita), so SC995-02 does not
occur.
• Program/Change Administrator will be displayed in Japanese, but this is normal.
16. Enter the SP mode and specify the following settings manually.
• a. SP5-985-001 (Device Setting: On Board NIC) Change the value from 0 to 1.
• b. SP5-985-002 (Device Setting: On Board USB) Change the value from 0 to 1.
17. Turn OFF the main power and then insert the SD card to which the NV-RAM data has been
uploaded in Slot 2.
18. Turn the main power ON.
19. Download the NV-RAM data stored in the SD card to the brand-new NV-RAM using
SP5-825-001 (NV-RAM Data Download).
The download will take a couple of minutes.
20. Change the Flair API SP values.
• SP1-041-001 (Scan:FlairAPI Setting): Change bit 0 from 0 to 1.
21. Turn the power OFF and remove the SD card from slot 2.
22. Turn the power ON.