SC6xx: Communication
D0CA/D0C9/D0C8/D0CB 6-56 SM
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC650-04 C Remote Service Modem Communication Error (dialup failing because of
incorrect modem configuration)
An error related to communication (dialup connection, modem board etc.)
using the RC Gate Type M was detected or an error that prevents RC
Gate operation was detected at power on.
Displayed only when an error is detected while RC Gate is operating.
SC is not issued if an error occurs during RC Gate installation (because it
can be referenced using SP).
SP settings invalid
Modem connector disconnected
Modem board disconnected
Wireless LAN card disconnected
Software bug.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC650-05 C Remote Service Modem Communication Error (Insufficient Current or
Connection Fault)
An error related to communication (dialup connection, modem board etc.)
using the RC Gate Type M was detected or an error that prevents RC
Gate operation was detected at power on.
Displayed only when an error is detected while RC Gate is operating.
SC is not issued if an error occurs during RC Gate installation (because it
can be referenced using SP).
SP settings invalid
Modem connector disconnected
Modem board disconnected
Wireless LAN card disconnected
The line is not supported and nothing can be done.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC650-13 C Remote Service Modem Communication Error (RC Gate Type M was
installed but modem is not present (detected during operation))
An error related to communication (dialup connection, modem board etc.)
using the RC Gate Type M was detected or an error that prevents RC
Gate operation was detected at power on.
Displayed only when an error is detected while RC Gate is operating.
SC is not issued if an error occurs during RC Gate installation (because
this error can be referred by using SP).