Main Machine Installation: Installation Procedures
SM 2-35 D0CA/D0C9/D0C8/D0CB
SP5-816-202.
3. Confirm the Request number, and then click [EXECUTE] with SP5-816-203.
4. Check the confirmation result with SP5-816-204.
Value Meaning Solution/ Workaround
0 Succeeded -
3 Communication error (proxy
enabled)
Check the network condition.
4 Communication error (proxy
disabled)
Check the network condition.
5 Proxy error (authentication error) Check Proxy user name and password.
6 Communication error Check the network condition.
8 Other error See "SP5816-208 Error Codes" below this.
9 Request number confirmation
executing
Processing… Please wait.
11 Already registered -
12 Parameter error -
20 Dial-up authentication error * These errors occur only in the modems that
support @Remote.
21 Answer tone detection error
22 Carrier detection error
23 Invalid setting value (modem)
24 Low power supply current
25 Modem unplugged
26 Busy line
5. Make sure that the screen displays the Location Information with SP5-816-205 only when it
has been input at the Center GUI.
6. Click [EXECUTE] to execute the registration with SP5-816-206.
7. Check the registration result with SP5-816-207.
Value Meaning Solution/ Workaround
0 Succeeded -
1 Request number error Check the request number again.
2 Already registered Check the registration status.
3 Communication error (proxy
enabled)
Check the network condition.
4 Communication error (proxy
disabled)
Check the network condition.
5 Proxy error (Authentication
error)
Check Proxy user name and password.
8 Other error See "SP5-816-208 Error Codes" below this.