Remote control commandsMXO 4 Series
525User Manual 1335.5337.02 ─ 07
Suffix:
<ch>
.
1 to 4, index of the analog channel
Return values:
<State> DETected | NDETected
*RST: NDETected
Usage: Query only
Asynchronous command
Manual operation: See "Predefined probe, name and type of the probe"
on page 126
PROBe<ch>:SETup:TYPE?
Queries the class of the probe.
Suffix:
<ch>
.
1 to 4, index of the analog channel
Return values:
<Type> String containing the probe class, e.g. None (no probe detec-
ted), passive, current, active diff., active single-ended.
Usage: Query only
Asynchronous command
Manual operation: See "Predefined probe, name and type of the probe"
on page 126
17.8.8.2 Settings for active voltage probes
The probe suffix <ch> selects the input channel to which the probe is connected.
PROBe<ch>:SETup:MODE.............................................................................................526
PROBe<ch>:SETup:ACCoupling..................................................................................... 526
PROBe<ch>:SETup:CMOFfset........................................................................................527
PROBe<ch>:SETup:DISPlaydiff.......................................................................................527
PROBe<ch>:SETup:ZAXV.............................................................................................. 528
PROBe<ch>:PMETer:STATe............................................................................................528
PROBe<ch>:PMETer:RESults:SINGle?............................................................................528
PROBe<ch>:PMETer:RESults:COMMon?........................................................................ 529
PROBe<ch>:PMETer:RESults:DIFFerential?.....................................................................529
PROBe<ch>:PMETer:RESults:NEGative?........................................................................ 529
PROBe<ch>:PMETer:RESults:POSitive?..........................................................................530
PROBe<ch>:SETup:ADVanced:AUDioverload.................................................................. 530
PROBe<ch>:SETup:ADVanced:FILTer............................................................................. 530
PROBe<ch>:SETup:ADVanced:RANGe........................................................................... 531
PROBe<ch>:SETup:ADVanced:PMToffset........................................................................ 531
Acquisition and setup

Table of Contents

Related product manuals