Remote control commands
R&S
®
RTP
1608User Manual 1337.9952.02 ─ 12
BUS<m>:UART:BAUDrate <Bitrate>
Same as BUS<m>:UART:BITRate.
Suffix:
<m>
.
1..4
Parameters:
<Bitrate> Range: 300 to 20000000
Increment: 1
*RST: 9600
Default unit: bps
Usage: Asynchronous command
BUS<m>:UART:PARity <Parity>
Defines the optional parity bit that is used for error detection.
See also: "Parity" on page 549.
Suffix:
<m>
.
1..4
Selects the serial bus.
Parameters:
<Parity> NONE | ODD | EVEN | MARK | SPC | DC
MARK
The parity bit is always a logic 1.
SPC
SPaCe: The parity bit is always a logic 0.
DC
Don't Care: the parity is ignored.
*RST: NONE
Usage: Asynchronous command
BUS<m>:UART:POLarity <Polarity>
Defines the idle state of the bus. The idle state corresponds to a logic 1. The transmit-
ted data on the bus is high (high = 1) or low (low = 1) active.
Suffix:
<m>
.
1..4
Selects the serial bus.
Parameters:
<Polarity> IDLLow | IDLHigh
*RST: IDLHigh
Usage: Asynchronous command
Protocols

Table of Contents

Other manuals for Rohde & Schwarz RTP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rohde & Schwarz RTP Series and is the answer not in the manual?

Rohde & Schwarz RTP Series Specifications

General IconGeneral
BrandRohde & Schwarz
ModelRTP Series
CategoryTest Equipment
LanguageEnglish

Related product manuals