Remote control commands
R&S
®
RTP
1609User Manual 1337.9952.02 ─ 12
BUS<m>:UART:SBIT <StopBits>
Sets the number of stop bits: 1; 1.5 or 2 stop bits are possible.
Suffix:
<m>
.
1..4
Selects the serial bus.
Parameters:
<StopBits> B1 | B15 | B2
*RST: B1
Usage: Asynchronous command
BUS<m>:UART:SSIZe <DataBits>
Sets the number of data bits in a message.
Suffix:
<m>
.
1..4
Selects the serial bus.
Parameters:
<DataBits> Number of data bits. 9 data bits are only possible with parity =
none.
Range: 5 to 9
Increment: 1
*RST: 8
Usage: Asynchronous command
BUS<m>:UART:PACKets <Packets>
Defines the method of packet separation. A packet is a number of subsequent words in
a date stream.
Suffix:
<m>
.
1..4
Selects the serial bus.
Parameters:
<Packets> NONE | EWORd | TOUT
NONE
Packets are not considered.
EWORd
End word, the end condition of a packet is a pattern. To define
the end word, use BUS<m>:UART:EWORd
TOUT
Defines a timeout between the packets. To set the timeout, use
BUS<m>:UART:TOUT
*RST: NONE
Protocols