Remote control commands
R&S
®
RTP
1621User Manual 1337.9952.02 ─ 12
TRIGger<m>:CAN:DMAX............................................................................................. 1625
TRIGger<m>:CAN:BORDer.......................................................................................... 1625
TRIGger<m>:CAN:DLCCondition...................................................................................1625
TRIGger<m>:CAN:DLC................................................................................................ 1625
TRIGger<m>:CAN:NDBYtes?........................................................................................1626
TRIGger<m>:CAN:FDATa:DPOPerator...........................................................................1626
TRIGger<m>:CAN:FDATa:DPOSition.............................................................................1626
TRIGger<m>:CAN:FDATa:DPTO................................................................................... 1627
TRIGger<m>:CAN:ACKerror......................................................................................... 1627
TRIGger<m>:CAN:BITSterror........................................................................................1627
TRIGger<m>:CAN:CRCerror.........................................................................................1627
TRIGger<m>:CAN:FORMerror...................................................................................... 1627
TRIGger<m>:CAN:FDATa:SCERror............................................................................... 1628
TRIGger<m>:CAN:TYPE <Type>
Selects the trigger type for CAN analysis.
See: "Trigger type" on page 564.
Parameters:
<Type> STOF | FTYP | ID | IDDT | ERRC
STOF
STart Of Frame: triggers on the first edge of the dominant SOF
bit (synchronization bit).
FTYP
Frame TYPe: triggers on a specified frame type (data, remote,
error, or overload) and on the identifier format.
To set the frame type, use TRIGger<m>:CAN:FTYPe. ´Set the
identifier format with TRIGger<m>:CAN:ITYPe
ID
IDentifier: Sets the trigger to one specific identifier or an identi-
fier range. To set the identifier, use TRIGger<m>:CAN:
ICONdition, TRIGger<m>:CAN:IMIN, and TRIGger<m>:
CAN:IMAX.
IDDT
IDentifier and DaTa: Combination of identifier and data condi-
tions To set the identifier condition, use TRIGger<m>:CAN:
ICONdition, TRIGger<m>:CAN:IMIN, and TRIGger<m>:
CAN:IMAX.
To set the data condition, use TRIGger<m>:CAN:DCONdition,
TRIGger<m>:CAN:DMIN, and TRIGger<m>:CAN:DMAX.
ERRC
ERRor Condition: Define the error types with
TRIGger<m>:CAN:ACKerror,
TRIGger<m>:CAN:BITSterror,
TRIGger<m>:CAN:CRCerror,
TRIGger<m>:CAN:FORMerror,
TRIGger<m>:CAN:FDATa:SCERror on page 1628.