Remote control commands
R&S
®
RTP
1640User Manual 1337.9952.02 ─ 12
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, Not equal, Less than, Less or equal than, Greater Than,
Greater or equal than. These condition require one identifier pat-
tern to be set with SEARch:TRIGger:CAN:IMIN.
INRange | OORange
In range / Out of range: Set the minimum and maximum value of
the range with SEARch:TRIGger:CAN:IMIN and SEARch:
TRIGger:CAN:IMAX.
*RST: EQUal
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:CAN:IMAX
<SearchName>,<IdPatternTo>
SEARch:TRIGger:CAN:IMAX? <SearchName>
Sets the the end value of an identifier range if SEARch:TRIGger:CAN:ICONdition
is set to INRange or OORange.
Parameters:
<IdPatternTo> Numeric or string pattern, see Chapter 22.4.6, "Bit pattern
parameter", on page 1148.
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:CAN:IMIN <SearchName>,<IdPattern>
SEARch:TRIGger:CAN:IMIN? <SearchName>
Specifies a message identifier pattern, or sets the the start value of an identifier range.
Parameters:
<IdPattern> Numeric or string pattern, see Chapter 22.4.6, "Bit pattern
parameter", on page 1148.
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:CAN:DCONdition <SearchName>,<DataOperator>
SEARch:TRIGger:CAN:DCONdition? <SearchName>
Sets the operator to set a specific data pattern or a data pattern range.
Parameters:
<DataOperator> EQUal | NEQual | LTHan | LETHan | GTHan | GETHan |
INRange | OORange
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, Not equal, Less than, Less or equal than, Greater Than,
Greater or equal than. These conditions require one data pattern
to be set with SEARch:TRIGger:CAN:DMIN.