Remote control commands
R&S
®
RTP
1715User Manual 1337.9952.02 ─ 12
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, Not equal, Less than, Less or equal than, Greater Than,
Greater or equal than. These conditions require one pattern to
be set with TRIGger<m>:ARINc:DATA:MIN.
INRange | OORange
In range/Out of range: set the minimum and maximum value of
the range with TRIGger<m>:ARINc:DATA:MIN and
TRIGger<m>:ARINc:DATA:MAX.
*RST: EQUal
TRIGger<m>:ARINc:DATA:MIN
<DataMin>
Defines the minimum bit pattern for the data.
Parameters:
<DataMin> Numeric or string pattern, see Chapter 22.4.6, "Bit pattern
parameter", on page 1148. The string parameter accepts the bit
value X (don't care).
TRIGger<m>:ARINc:DATA:MAX <DataMax>
Sets the end value of a data pattern if TRIGger<m>:ARINc:DATA:CONDition is set
to INRange or OORange.
Parameters:
<DataMax>
TRIGger<m>:ARINc:ERRor:CODing <CodingError>
Enables triggering when a coding error occurs.
Parameters:
<CodingError> ON | OFF
*RST: ON
TRIGger<m>:ARINc:ERRor:PARity <ParityError>
Enables triggering when a parity error occurs.
Parameters:
<ParityError> ON | OFF
*RST: ON