Remote control commands
R&S
®
RTP
1720User Manual 1337.9952.02 ─ 12
BUS<m>:ARINc:WORD<n>:STARt?
Returns the start time of the specified word.
Suffix: 
<m>
.
1..4
<n> *
Return values: 
<FrameStart> Range:  -100E+24  to  100E+24
Increment:  100E-12
*RST:  0
Default unit: s
Usage:  Query only
BUS<m>:ARINc:WORD<n>:STATe?
Returns the overall state of the specified word.
Suffix: 
<m>
.
1..4
Selects the serial bus.
<n> *
Selects the word.
Return values: 
<FrameState> OK | CODE | GAP | PAR
CODE: coding error occured.
GAP: timing gap error occured.
PAR: parity error occured.
*RST:  OK
Usage:  Query only
BUS<m>:ARINc:WORD<n>:STOP?
Returns the end time of the specified word.
Suffix: 
<m>
.
1..4
<n> *
Return values: 
<FrameStop> Range:  -100E+24  to  100E+24
Increment:  100E-12
*RST:  0
Default unit: s
Usage:  Query only
Protocols