Remote control commands
R&S
®
RTP
1838User Manual 1337.9952.02 ─ 12
SEARch:TRIGger:RFFE:ERRor:SSC <SearchName>,<SSCError>
SEARch:TRIGger:RFFE:ERRor:SSC? <SearchName>
Enables the search for SSC errors - when no valid SSC sequence has been found
after the idle time.
Parameters:
<SSCError> ON | OFF
*RST: ON
Parameters for setting and query:
<SearchName> String parameter
SEARch:TRIGger:RFFE:ERRor:GAP
<SearchName>,<GapError>
SEARch:TRIGger:RFFE:ERRor:GAP? <SearchName>
Enables the search for RFFE gap time error.
Parameters:
<GapError> ON | OFF
*RST: ON
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:RFFE:ERRor:VERSion <SearchName>,<VersionError>
SEARch:TRIGger:RFFE:ERRor:VERSion? <SearchName>
Enables the search for RFFE vresion error.
Parameters:
<VersionError> ON | OFF
*RST: ON
Parameters for setting and query:
<SearchName>
22.17.13.5 Search results
The search on decoded RFFE data returns the same results as the queries for decode
results.
In all SEARch:RESult:RFFE commands, the suffix <m> selects the command
sequence. Suffix <n> selects index of byte inside a command sequence.
In search result commands, you have to specify the <SearchName> parameter. It is a
string parameter that contains the search definition name.
For a description of the returned values, see the corresponding commands in Chap-
ter 22.17.13.3, "Decode results", on page 1826.
For programming example, see "Searching RFFE data" on page 1140.
Protocols