Remote control commands
R&S
®
RTP
1929User Manual 1337.9952.02 ─ 12
<n> *
Specifies the field number within the frame.
Parameters:
<DataMin> Specifies the name of the generic trigger setting frame.
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:MPHY:SSIC:DOPerator <SearchName>,<Frame>, <Field>,
<Operator>
SEARch:TRIGger:MPHY:SSIC:FRAMe<m>:FLD<n>:DOPerator
<SearchName>,<DataOperator>
SEARch:TRIGger:MPHY:SSIC:FRAMe<m>:FLD<n>:DOPerator? <SearchName>
Sets the operator to set a specific data pattern to be searched in the selected field of
the selected frame.
Suffix:
<m>
.
*
Specifies the frame number.
<n> *
Specifies the field number within the frame.
Parameters:
<DataOperator> EQUal | NEQual | LTHan | LETHan | GTHan | GETHan |
INRange | OORange
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, Not equal, Less than, Less than or equal, Greater than,
Greater than or equal. These conditions require one endpoint
value to be set using SEARch:TRIGger:MPHY:SSIC:
FRAMe<m>:FLD<n>:DMIN.
INRange | OORange
In range, out of range. These conditions require a range of end-
point values to be set using SEARch:TRIGger:MPHY:SSIC:
FRAMe<m>:FLD<n>:DMIN and SEARch:TRIGger:MPHY:
SSIC:FRAMe<m>:FLD<n>:DMAX.
*RST:
EQUal
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:MPHY:SSIC:FRENable <SearchName>,<Frame>, <Enabler>
Setting parameters:
<SearchName>
<Frame>
<Enabler> ON | OFF
Usage: Setting only
Protocols