EasyManua.ls Logo

Rohde & Schwarz RTP Series - Page 1949

Rohde & Schwarz RTP Series
2403 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commands
R&S
®
RTP
1949User Manual 1337.9952.02 ─ 12
TRIGger<m>:CMSB:IMAX <DataPositionTo>
Sets the end value of the bit index range (data position range), if TRIGger<m>:CMSB:
ICONdition on page 1948 is set to "INRange".
Suffix:
<m>
.
1..3
Parameters:
<DataPositionTo> Range: 0 to 65535
Increment: 1
*RST: 65535
TRIGger<m>:CMSB:NRZ:WRDLength
<NRZWordLength>
Sets the number of bits in an NRZ Unclocked word.
Suffix:
<m>
.
1..3
Parameters:
<NRZWordLength> Range: 0 to 31
Increment: 1
*RST: 8
TRIGger<m>:CMSB:ADVanced:FRAMe<n>:ENABle <Enable>
TRIGger<m>:CMSB:ADVanced:FRENable <Frame>, <Enabler>
Enables or disables the specific frame to be triggered on.
Suffix:
<m>
.
1..3
Only 1 = A-trigger, 2 | 3 = not available. Can be omitted.
Setting parameters:
<Frame>
<Enabler> ON | OFF
Example:
:TRIGger:CMSB:ADVanced:FRENable "Master" 1
Enables the Master frame.
:TRIGger:CMSB:ADVanced:FRAMe1:ENABle 1
Enables the 1st frame that you have defined.
Usage: Setting only
TRIGger<m>:CMSB:ADVanced:FRAMe<n>:FLD<o>:ENABle <CondEnabler>
TRIGger<m>:CMSB:ADVanced:FIENable <Frame>, <Field>, <Enabler>
Enables or disables the specific field within the defined frame to be triggered on.
Suffix:
<m>
.
1..3
Only 1 = A-trigger, 2 | 3 = not available. Can be omitted.
Protocols

Table of Contents

Other manuals for Rohde & Schwarz RTP Series