Remote control commands
R&S
®
RTP
1987User Manual 1337.9952.02 ─ 12
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:EBTB:TYPE <SearchName>,<Type>
SEARch:TRIGger:EBTB:TYPE? <SearchName>
Selects the type of condition to be searched for. You can search for a certain symbol or
enable a specific error condition.
Parameters:
<Type> SYMBol | ERRor
*RST: SYMBol
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:EBTB:UNK
<SearchName>,<UnkError>
SEARch:TRIGger:EBTB:UNK? <SearchName>
Defines, if a search for any unknown symbol error is activated or not.
Parameters:
<UnkError> ON | OFF
*RST: OFF
Parameters for setting and query:
<SearchName>
22.17.17.5 Search results
In all SEARch:RESult:EBTB:SYMBol<m> commands, the suffix <m> selects the
frame number in the list of search results.
SEARch:RESult:EBTB:SCOunt?................................................................................... 1987
SEARch:RESult:EBTB:SYMBol<m>:DATA?....................................................................1988
SEARch:RESult:EBTB:SYMBol<m>:STARt?...................................................................1988
SEARch:RESult:EBTB:SYMBol<m>:STATus?.................................................................1988
SEARch:RESult:EBTB:SYMBol<m>:STOP?................................................................... 1989
SEARch:RESult:EBTB:SCOunt? <SearchName>
Returns the symbol count, i.e. the number of symbols found in the specified search
result.
Query parameters:
<SearchName>
Return values:
<Count> Range: 0 to 100000
Increment: 1
*RST: 0
Protocols