Remote control commands
R&S
®
RTP
2137User Manual 1337.9952.02 ─ 12
TRIGger<m>:PCIE:OSET:TYPE <Type>
Sets the ordered set to be triggered on.
Parameters:
<Type> | SDS
SKP
SKP ordered sets
TS1
Training sequence 1
TS2
Training sequence 2
FTS
Fast training sequence
EIOS
Electrical idle ordered set
EIEOS
Electrical idle exit ordered set
COMP
Compliance pattern
SDS
Start of data sequence
*RST:
SKP
TRIGger<m>:PCIE:TLP:ADRT <AddressType>
Sets the address type to be triggered on for the transaction layer type trigger.
Parameters:
<AddressType> ANY | X32 | X64
*RST: ANY
TRIGger<m>:PCIE:TLP:CFGT <ConfigType>
Sets the configuration type to be triggered on for the transaction layer type trigger.
Parameters:
<ConfigType> ANY | TYPE0 | TYPE1
*RST: ANY
TRIGger<m>:PCIE:TLP:CPID <TLPCompleterID>
Sets the completer ID to be triggered on for the transaction layer type trigger.
Parameters:
<TLPCompleterID> 16-bit pattern, see Chapter 22.4.6, "Bit pattern parameter",
on page 1148. The string parameter accepts the bit value X
(don't care).