Remote control commands
R&S
®
RTP
2194User Manual 1337.9952.02 ─ 12
Usage: Event
Asynchronous command
EYE<m>:FILTer:BPATtern:SRIGht
Shifts the pattern one bit to the right.
Suffix:
<m>
.
1..4
Usage: Event
Asynchronous command
EYE<m>:FILTer:BPATtern:RESet
Resets the bit sequence filter to the default (DC for all bits).
Suffix:
<m>
.
1..4
Usage: Event
Asynchronous command
EYE<m>:FILTer:DDR:FTYPe <CommTyp>
Sets which frame types contribute to the eye diagram.
Suffix:
<m>
.
1..4
Parameters:
<CommTyp> ANY | ANYC | READ | WRITe | RDNC | WRNC
ANYC: any consecutive
RDNC: read non-consecutive
WRNC: write non-consecutive
*RST: ANY
Usage: Asynchronous command
EYE<m>:FILTer:DDR:LENerror <CommTyp>
If enabled, the length errors contribute to the eye diagram.
Suffix:
<m>
.
1..4
Parameters:
<CommTyp> ON | OFF
*RST: OFF
Usage: Asynchronous command