EasyManua.ls Logo

Rohde & Schwarz RTP Series - Page 867

Rohde & Schwarz RTP Series
2403 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Protocol analysis
R&S
®
RTP
867User Manual 1337.9952.02 ─ 12
"Data pattern"
Sets the trigger to a defined data pattern or pattern range.
"NULL frame"
Sets the trigger to a null frame, a frame without usable data.
"Time Code"
Sets the trigger to a time-code control code. You can define the data
pattern of the time code to be triggered on.
"Errors"
Triggers on an enabled error type.
Remote command:
TRIGger<m>:SWIRe:TYPE on page 2112
Trigger Control Type
Triggers on a specific control type character.
"ANY"
Any control type character
"FCT"
Flow control token character
"EOP"
Normal end of packet character
"EEP"
Error end of packet character
Remote command:
TRIGger<m>:SWIRe:CTYPe on page 2109
Data (Time Code)
Sets the specified data type for the time code to be triggered on. The trigger data setup
consists of a comparison condition and one or two data patterns.
In binary format, use the following characters: 1; 0; or X (do not care). To enter the pat-
tern in other formats use the bit pattern editor, see Chapter 13.1.7, "Bit pattern editor",
on page 519.
"Condition"
Sets the comparison condition to a specific value or a range.
"Data Min/
Data"
Specifies the value or sets the start value of a range.
"Data Max"
Sets the maximum value of a range for "Condition" = "In range"/"Out
of range".
Remote command:
TRIGger<m>:SWIRe:TIME:CONDition on page 2111
TRIGger<m>:SWIRe:TIME:MAX on page 2111
TRIGger<m>:SWIRe:TIME:MIN on page 2111
SpaceWire (option R&S
RTP-K65)