TX300 S8 / RX350 S8 Upgrade and Maintenance Manual 161
6 Power supply
This chapter provides information on how to install, remove or replace power
supply units (PSU) and how to replace the power backplane.
The PRIMERGY TX300 S8 / RX350 S8 server can be equipped with up to four
hot-plug PSU modules. Power redundancy is possible in various PSU
configurations (see section "PSU installation sequence" on page 164).
Safety notes
V CAUTION!
Do not disassemble the power supply unit. Doing so may cause
electric shock.
Areas around the power supply unit may remain extremely hot after
shutdown. After shutting down the server, wait for hot components to
cool down before removing the power supply unit.
When installing a power supply unit, ensure that the connector of the
power supply unit is not damaged or bent.
If the power supply unit is hard to remove, do not pull it out by force.
The power supply unit is heavy, so handle it carefully. If you drop it by
mistake, injuries may result.
For further safety information, please refer to chapter "Important
information" on page 45.