TX300 S8 / RX350 S8 Upgrade and Maintenance Manual 65
Basic hardware procedures
4.4.1 Preliminary steps
Ê "Shutting down the server" on page 62
Ê "Disconnecting the server from the mains" on page 63
Ê Remove all remaining external cables from the rear connector panel and
expansion cards. For further information, refer to section "Connectors and
indicators" on page 776.
4.4.2 Extending the server out of the rack
Figure 10: Extending the server out of the rack
Ê Shut down the server and remove external cables as described in section
"Preliminary steps" on page 65.
Ê If you are not using a cable mounting arm (CMA kit), ensure that the rear
cables are long enough not to be strained or damaged when extending the
server out of the rack.
Ê Fold down the two quick release levers on the rack mounting frame (1) and
pull the server out of the rack until it locks in place (2).
V CAUTION!
Do not use the extended server as a surface on which to put things or as
a work surface, and strictly avoid leaning on or against it.