TX300 S8 / RX350 S8 Upgrade and Maintenance Manual 727
Converting a tower server to a rack server
15.6 Removing glider feet
Figure 570: Removing glider feet
Ê Using a slotted screw driver, slightly pry up on each glider foot until it
detaches.
Ê Bring the server back to its horizontal position.
I At least two people are needed to turn over a fully equipped server.
Remove hard disk drives and power supply modules in order to
facilitate the task.
15.7 Preparing the intrusion switch
Ê Remove the intrusion switch module as described in section "Removing the
intrusion switch cable" on page 762.
Ê Attach a rubber bumper (C26192-Y26-C43) to the front intrusion switch and
reinstall the intrusion switch module as described in section "Installing the
intrusion switch cable" on page 765.