EasyManua.ls Logo

Fujitsu PRIMERGY RX350 S8

Fujitsu PRIMERGY RX350 S8
792 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TX300 S8 / RX350 S8 Upgrade and Maintenance Manual 59
Basic hardware procedures
4.1.2.1 Global Error indicator
Figure 4: Global Error indicator on front panel
Ê Check the Global Error indicator on the front or connector panel of the
server:
Ê For further diagnostics, proceed as follows:
Hardware errors:
Check the System Event Log (SEL) as described in section "Viewing the
SEL" on page 149.
Software / agent related errors:
Check the ServerView System Monitor, available on Windows or Linux
based servers with ServerView agents installed.
I
For further information, please refer to the "ServerView System
Monitor" user guide.
Indicator Status Description
Global error
indicator
off no critical event (non CSS component)
orange on
prefailure detected (non CSS component),
requires (precautionary) service
intervention
orange
flashing
non CSS component failure or software /
agent related error, requires service
intervention

Table of Contents

Related product manuals