TX300 S8 / RX350 S8 Upgrade and Maintenance Manual 551
Accessible drives
12.5.1.1 Preliminary steps
Ê "Shutting down the server" on page 62
Ê "Disconnecting the server from the mains" on page 63
Ê When working on a rack-mounted server:
"Extending / removing the server from the rack" on page 64
Ê "Opening the server" on page 68
I The front cover only needs to be removed in order to remove
accessible drive dummy covers (see section "Removing accessible
drive dummy covers" on page 533). If the Multibay box is already
installed in the server and will be removed in order to install a slimline
ODD or LSD module, skip this step.
Ê "Removing the system air duct" on page 81
Ê "Removing the system fan holder" on page 330
Ê If the Multibay box is already installed in the server, disconnect all cables
from the slimline ODD or LSD module and remove the box as described in
section "Removing the Multibay box" on page 568.
12.5.1.2 Installing the slimline ODD into the Multibay box
Ê Press up on the locking tab to disengage the slimline ODD dummy module
as shown in figure 431 on page 563.
Ê From inside the Multibay module, press out on the ODD dummy module and
pull it out of its bay.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX350 S8 and is the answer not in the manual?

Fujitsu PRIMERGY RX350 S8 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY RX350 S8
CategoryServer
LanguageEnglish

Related product manuals