486 HEIDENHAIN Technical Manual MANUALplus 620
mFunTimeAllow
115003
General time allowance for M function
Defines the time for the execution of M functions
to be generally taken into account during the
simulation.
Format: Numerical value
Input: 0.000 to 10 000 000 [s]
Default: 0
PLC/Pgm
run is
locked
LEVEL1
1423
ProcessingTime
Specific time allowances for M functions
CfgmFunKeys
Assignment of specific time allowances for selected M functions
mFunTimeKeys
115401
List of the key names of all M functions with
specific time allowances.
Enter the key names of the M functions that are
to have specific time allowances.
Format: List [0 to 30]
Input: Key name from
CfgTimeDetMfun
PLC/Pgm
run is
locked
LEVEL1
1424
CfgTimeDetMfun
Specific time allowances for selected M functions
[Key name of the M function]
mFun
115101
Number of the M function
Number of the M function for which a specific
time allowance is to be defined.
Format: Numerical value
Input: 0 to 999
Default: 0
PLC/Pgm
run is
locked
LEVEL1
1424
timeAllow
115102
Time allowance of the M function
Time allowance that is to be taken into account for
the execution of this M function during the
simulation in addition to the general time
allowance for M functions from
MP_mFunTimeAllow.
Format: Numerical value
Input: 0.000 to 10 000 000 [s]
Default: 0
PLC/Pgm
run is
locked
LEVEL1
1424