January 2012 4.10 List of Machine Parameters 513
isHirth
300103
MP420
(optional parameter)
Axis with Hirth coupling
Default grid increment in [°] or [mm] for Hirth
coupling, measured from the machine datum.
If the parameter is inactive or the value 0 is
entered, no Hirth grid is supported.
Format: Numerical value
Input: Hirth grid in [°] or [mm]
RUN
LEVEL3
597 110-02
703
axisHw
300104
Hardware to which the axis is connected
Format: Selection menu
Input:
None:
No hardware connection (virtual axis)
InOutCC:
Digital axis with connection to a CC controller
unit
AnalogMC:
Analog drive interface; encoder connection to
the MC
AnalogCC:
Analog drive interface; encoder connection to
the CC
DisplayMC:
Display axis; encoder connection to the MC
DisplayCC:
Display axis; encoder connection to the CC
ManualMC:
Open-loop axis; encoder connection to the MC
ManualCC:
Open-loop axis; encoder connection to the CC
ProfiNet:
Digital Profinet axis (reserved, function not
available yet)
Default: InOutCC
RESET
LEVEL3
635
Parameter
MP number
iTNC MP number
Function and input Reaction/
Access
Page