January 2012 4.10 List of Machine Parameters 515
noActToNumAtEmSt
300109
(optional parameter)
Actual-to-nominal vaIue transfer for all axes in
an EMERGENCY STOP
Format: Selection menu
Input:
TRUE:
Actual-to-nominal value transfer for all axes in
an EMERGENCY STOP is not performed.
FALSE:
The standard control behavior is actual-to-
nominal value transfer for all axes in an
EMERGENCY STOP.
Default: FALSE
RUN
LEVEL3
638
deactivatedAtStart
300110
(optional parameter)
Deactivate axis during startup
Format: Selection menu
Input:
TRUE:
During startup of the MANUALplus 620 the axis
is deactivated—irrespective of the parameter
MP_axisHw. The same effect is attained with
the setting as from calling PLC module 9226 or
9418 with mode 14.
FALSE:
During startup of the MANUALplus 620 the axis
is treated as configured in the parameter
axisHw.
Default: FALSE
RUN
LEVEL3
682
advancedSettings
300112
(optional parameter)
Advanced settings for individual axes
Format: Bit-encoded value
Input:
Bit 0 = 1:
A traverse commanded by the PLC is not
interrupted if the touch probe is deflected.
Bit 1 = 1:
A traverse commanded by the PLC is not made
in a bell-shaped curve but at a constant
acceleration.
Bit 2 = 1:
For a spindle in position feedback control, the
following error is not calculated in modulo
counting mode.
All other bits: Reserved
RUN
LEVEL3
597 110-05
640
Parameter
MP number
iTNC MP number
Function and input Reaction/
Access
Page