January 2012 1.3 NC Software 548 328-04 67
400313 CfgFeedLimits MP_limitSpeedAcc For spindle in speed control loop
(M3/M4/M5):
Limit speed for reduction of the
acceleration, see page 1011.
400314 MP_limitSpeedDec For spindle in speed control loop
(M3/M4/M5):
Limit speed for reduction of the
braking deceleration, see page
1011.
400315 MP_limitAccSpeedCtrl For spindle in speed control loop
(M3/M4/M5):
Absolute acceleration. Effective
above MP_limitSpeedAcc, see
page 1011.
400316 MP_limitDecSpeedCtrl For spindle in speed control loop
(M3/M4/M5):
Absolute deceleration during
braking. Effective above
MP_limitSpeedDec, see page
1011.
400413 CfgReferencing MP_externRefPulse Referencing with external
reference signal (X30 or –SP.REF
for HSCI), see page 1005.
400928 CfgSpeedControl MP_vCtrlTimeSwitchOff Pulse switch-off of the power
modules. Monitoring time for the
braking process. If after the time
has expired the axes are still in
motion, the pulses of the power
modules are switched off, see
page 991.
400930 MP_vCtrlSpinSpeedTol Monitoring of the spindle speed;
useful during power milling, for
example. Specify the permissible
lower spindle speed limit, see
page 1026.
400931 MP_vCtrlSpinMinSpeed Minimum spindle speed as of
which the monitoring in
MP_vCrtrlSpinSpeedTol becomes
active, see page 1026.
400932 MP_vCtrlEncInputFunc Only in effect with CC 61xx:
Specify the maximum input
frequency of the motor encoder,
see page 1044.
400933 MP_delayEmStopSpin Delay of emergency-stop reaction
of spindles, see page 1026.
401323 CfgServoMotor MP_testBrakeCurrent Test of motor brake: Factor for
motor stall current, see page 987.
401324 MP_testBrakeTolerance Test of motor brake: Maximum
permissible path, see page 987.
MP
number
Config object Parameter Description