Remote control commands
R&S
®
RTP
1862User Manual 1337.9952.02 ─ 12
*RST: HS_SOP
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:DPHY:DATA:CONDition <SearchName>,<Format>
SEARch:TRIGger:DPHY:DATA:CONDition? <SearchName>
Set the condition for the data value. You can define an exact value or a value range.
Parameters:
<Format> EQUal | NEQual | LTHan | LETHan | GTHan | GETHan |
INRange | OORange
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, Not equal, Less than, Less or equal than, Greater Than,
Greater or equal than. These conditions require one data pattern
to be set with the corresponding SEARch:TRIGger:DPHY:
DATA:MIN command.
INRange | OORange
In range/Out of range: set the minimum and maximum value of
the range with SEARch:TRIGger:DPHY:DATA:MIN and
SEARch:TRIGger:DPHY:DATA:MAX.
*RST:
EQUal
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:DPHY:DATA:MAX <SearchName>,<DataMax>
SEARch:TRIGger:DPHY:DATA:MAX? <SearchName>
Sets the the end value of a data type range if SEARch:TRIGger:DPHY:DATA:
CONDition is set to INRange or OORange.
Parameters:
<DataMax> Numeric or string pattern, see Chapter 22.4.6, "Bit pattern
parameter", on page 1148. The string parameter accepts the bit
value X (don't care).
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:DPHY:DATA:MIN <SearchName>,<DataMin>
SEARch:TRIGger:DPHY:DATA:MIN? <SearchName>
Specifies a data bit pattern, or sets the the start value of a pattern range.
Parameters:
<DataMin> Numeric or string pattern, see Chapter 22.4.6, "Bit pattern
parameter", on page 1148. The string parameter accepts the bit
value X (don't care).
Protocols