Remote control commands
R&S
®
RTP
1885User Manual 1337.9952.02 ─ 12
TRIGger<m>:MPHY:DATA:ICONdition <DataIdxOperator>
Sets the condition for the index. You can define an exact value or a value range.
Suffix:
<m>
.
1..3
Parameters:
<DataIdxOperator> EQUal | LTHan | LETHan | GTHan | GETHan | INRange |
RANGe
EQUal | LTHan | LETHan | GTHan | GETHan
Equal, Less than, Less or equal than, Greater Than, Greater or
equal than. These conditions require one pattern to be set with
the corresponding TRIGger<m>:MPHY:DATA:IMIN command.
INRange = RANGe
In range: Set the minimum and maximum value using
TRIGger<m>:MPHY:DATA:IMIN and TRIGger<m>:MPHY:
DATA:IMAX.
*RST: INRange
TRIGger<m>:MPHY:DATA:IMIN <DataIndexMin>
Specifies the index minimum, or sets the start value of a range.
Suffix:
<m>
.
1..3
Parameters:
<DataIndexMin> Range: 1 to 0
Increment: 1
*RST: 1
TRIGger<m>:MPHY:DATA:IMAX <DataIndexMax>
Sets the end value of the index range if TRIGger<m>:MPHY:DATA:ICONdition is
set to INRange or RANge.
Suffix:
<m>
.
1..3
Parameters:
<DataIndexMax> Range: 1 to 0
Increment: 1
*RST: 0
TRIGger<m>:MPHY:FSNumber:CONDition <FSNOperator>
Sets the condition for FSN. You can define an exact value or a value range.
Protocols