Remote control commands
R&S
®
RTP
1921User Manual 1337.9952.02 ─ 12
TRIGger<m>:MPHY:SSIC:ERENable.............................................................................1921
TRIGger<m>:MPHY:SSIC:ERRor<n>:ENABle................................................................ 1921
TRIGger<m>:MPHY:SSIC:FRENable.............................................................................1921
TRIGger<m>:MPHY:SSIC:FRAMe<n>:ENABle............................................................... 1921
TRIGger<m>:MPHY:SSIC:FIENable.............................................................................. 1922
TRIGger<m>:MPHY:SSIC:FRAMe<n>:FLD<o>:ENABle.................................................. 1922
TRIGger<m>:MPHY:SSIC:BIT.......................................................................................1922
TRIGger<m>:MPHY:SSIC:FRAMe<n>:FLD<o>:BIT.........................................................1922
TRIGger<m>:MPHY:SSIC:DMAX...................................................................................1923
TRIGger<m>:MPHY:SSIC:FRAMe<n>:FLD<o>:DMAX.................................................... 1923
TRIGger<m>:MPHY:SSIC:DMIN....................................................................................1923
TRIGger<m>:MPHY:SSIC:FRAMe<n>:FLD<o>:DMIN......................................................1923
TRIGger<m>:MPHY:SSIC:DOPerator............................................................................ 1923
TRIGger<m>:MPHY:SSIC:FRAMe<n>:FLD<o>:DOPerator.............................................. 1923
TRIGger<m>:MPHY:SSIC:IMAX....................................................................................1924
TRIGger<m>:MPHY:SSIC:FRAMe<n>:FLD<o>:IMAX......................................................1924
TRIGger<m>:MPHY:SSIC:IMIN..................................................................................... 1924
TRIGger<m>:MPHY:SSIC:FRAMe<n>:FLD<o>:IMIN.......................................................1924
TRIGger<m>:MPHY:SSIC:IOPerator..............................................................................1925
TRIGger<m>:MPHY:SSIC:FRAMe<n>:FLD<o>:IOPerator................................................1925
TRIGger<m>:MPHY:SSIC:ERENable <ErrorName>, <Enabler>
TRIGger<m>:MPHY:SSIC:ERRor<n>:ENABle <Enable>
Enables or disables the trigger on an error condition.
Suffix:
<m>
.
1..3
<n> *
Parameters:
<Enable> ON | OFF
*RST: ON
Example: Trigger on CRC and length errors:
TRIGger:MPHY:SSIC:ERRor1:ENABle ON
Enables CRC Error.
TRIGger:MPHY:SSIC:ERENable "Length Error",ON
Enables Length Error.
TRIGger<m>:MPHY:SSIC:FRENable <Frame>, <Enabler>
TRIGger<m>:MPHY:SSIC:FRAMe<n>:ENABle <Enable>
Enables or disables the checking condition for the selected frame.
Suffix:
<m>
.
1..3
Only 1 = A-trigger, 2 | 3 = not available. Can be omitted.
<n> *
Specifies the field number within the frame.
Protocols