Remote control commands
R&S
®
RTP
1939User Manual 1337.9952.02 ─ 12
Suffix: 
<m>
.
1..4
Parameters:
<HystClock> Range:  -25  to  25
Increment:  0.1
*RST:  0.1
Default unit: V
BUS<m>:CMSB:NRZ:THReshold:DATA <ThresholdData>
Sets the threshold for the data signal digitization in NRZ coding standards.
Suffix: 
<m>
.
1..4
Parameters:
<ThresholdData> Range:  -25  to  25
Increment:  0.1
*RST:  2
Default unit: V
BUS<m>:CMSB:NRZ:HYSTeresis:DATA <HystData>
Sets the hysteresis size on the data line channel.
Suffix: 
<m>
.
1..4
Parameters:
<HystData> Range:  -25  to  25
Increment:  0.1
*RST:  0.1
Default unit: V
BUS<m>:CMSB:NRZ:THReshold:ENBLe <ThresholdEnable>
Sets the threshold for the enable signal digitization in NRZ coding standards.
Suffix: 
<m>
.
1..4
Parameters:
<ThresholdEnable> Range:  -25  to  25
Increment:  0.1
*RST:  2
Default unit: V
BUS<m>:CMSB:NRZ:HYSTeresis:ENBLe <HystEnable>
Sets the hysteresis size on the enable line channel.
Protocols