Protocol analysis
R&S
®
RTP
621User Manual 1337.9952.02 ─ 12
"Label Min"
Defines the bit pattern of the label.
In binary format, use the following characters: 1; 0; or X (do not care).
To enter the pattern in other formats use the bit pattern editor, see
Chapter 13.1.7, "Bit pattern editor", on page 519.
"Label Max"
The second label pattern is required to specify a range with condi-
tions "In range" and "Out of range".
Remote command:
TRIGger<m>:ARINc:LABel:CONDition on page 1716
TRIGger<m>:ARINc:LABel:MIN on page 1716
TRIGger<m>:ARINc:LABel:MAX on page 1716
Data setup: Condition, Data Min, Data Max ← Label + Data
The data setup consists of the condition and one or two data patterns.
"Condition"
Defines the operator to set a specific data ("Equal" or "Not equal") or
a data range.
"Data Min"
Defines the bit pattern of the data.
In binary format, use the following characters: 1; 0; or X (do not care).
To enter the pattern in other formats use the bit pattern editor, see
Chapter 13.1.7, "Bit pattern editor", on page 519.
"Data Max"
The second data pattern is required to specify a range with conditions
"In range" and "Out of range".
Remote command:
TRIGger<m>:ARINc:DATA:CONDition on page 1714
TRIGger<m>:ARINc:DATA:MIN on page 1715
TRIGger<m>:ARINc:DATA:MAX on page 1715
SDI / SSM ← Label + Data
Sets the values for the source/destination identifier (SDI) and the sign/status matrix
(SSM) bits.
Remote command:
TRIGger<m>:ARINc:SDI on page 1717
TRIGger<m>:ARINc:SSM on page 1717
Error Conditions
Specifies the error conditions to be triggered on.
Coding error ← Error Conditions
Triggers on a coding error.
Remote command:
TRIGger<m>:ARINc:ERRor:CODing on page 1715
Parity Error ← Error Conditions
Checks the parity and triggers if the parity is even.
Remote command:
TRIGger<m>:ARINc:ERRor:PARity on page 1715
ARINC 429 (option R&S