Protocol analysis
R&S
®
RTP
635User Manual 1337.9952.02 ─ 12
"Bit index oper-
ator"
Sets the operator ("Equal", "Greater or equal", or "In range").
"Bit index"
Sets the bit index (data position), or the start value of a bit index
range.
"Bit index to"
Sets end value of a bit index range (data position range). Available
only, if the "Bit index operator" is set to "In range".
Destination Address
Defines the destination address.
"Condition"
Sets the comparison condition to a specific value or a range.
"Destinataion
Address (Min)"
Specifies the value or sets the start value of a range.
"Destinataion
Adress (Max)"
Sets the maximum value of a range for "Condition" = "In range"/"Out
of range".
Remote command: 
TRIGger<m>:ETHernet:FRAMe:DCONdition on page 1732
TRIGger<m>:ETHernet:FRAMe:DMAX on page 1733
TRIGger<m>:ETHernet:FRAMe:DMIN on page 1733
Source Address
Defines the source address, the physical address of the device that sends the frame.
"Condition"
Sets the comparison condition to a specific value or a range.
" Source
Address (Min)"
Specifies the value or sets the start value of a range.
"Source
Adress (Max)"
Sets the maximum value of a range for "Condition" = "In range"/"Out
of range".
Remote command: 
TRIGger<m>:ETHernet:FRAMe:SCONdition on page 1733
TRIGger<m>:ETHernet:FRAMe:SMAX on page 1733
TRIGger<m>:ETHernet:FRAMe:SMIN on page 1734
Length/ Type
Defines the length/type field value.
"Condition"
Sets the operator to trigger on a specific address pattern ("Equal" or
"Not equal") or an address range.
"Length/Type
(Min)"
Defines the length/type pattern for all operators that require one pat-
tern.
"Length/Typ
(Max)"
Defines the length/type pattern that is required to specify a range with
conditions "In range" and "Out of range".
Remote command: 
TRIGger<m>:ETHernet:FRAMe:TCONdition on page 1734
TRIGger<m>:ETHernet:FRAMe:TMAX on page 1734
TRIGger<m>:ETHernet:FRAMe:TMIN on page 1734
Ethernet 10BASE-T and 100BASE-TX (option R&S