RTC6 boards
Doc. Rev. 1.0.21 en-US
16 Appendix A: The RTC6 Ethernet Board
912
16.7.5 Control Commands Allowed
for Automatic Booting
• Only certain control commands are allowed in
each boot phase, see table 8 and Chapter 16.7.6
”Automatic Booting – Process in Detail”,
page 914:
– Boot Phase 1
– Boot Phase 2
• They meet one or more of the following criteria:
– Requires no communication with the PC
– Does not send a response to the PC
– There is no corresponding list command
• Exceptions are, for example,
– set_free_variable, see Comments there
– set_auto_laser_control or
set_scanahead_params
• They check the connected scan systems at
point in time of the call
• They save exclusively the parameters to be
finally set only in case of success
– set_jump_mode only sets the tuning numbers
VA1
…
JB2
during automatic booting and does
not check whether they match the scan system.
– The table containing the Jump Delay values
[JumpTable<No>]
, see page 219 and
load_jump_table_offset, must have been
previously saved via create_dat_file.
• Upon (later) automatic booting, the connected
scan systems are not checked anymore!
• Boot Phase 2-control commands are control
commands which:
– Necessarily need to be executed after a
Boot Phase 1-control command
– Require functioning peripherals, for example,
an iDRIVE scan system
(1)
with “Automatic Laser
Control“. Important: users must make sure
themselves that the periphery is actually
working at runtime
(1) See Glossary entry on page 27.