16 Appendix A: The RTC6 Ethernet Board
918
innovators for industry
16.9.3 Enabling
Remote Interface Mode
(1) Configure the RTC6 Ethernet Board for
Standalone Operation Mode in
“Standalone Full State“, see Chapter 16.7.3
”Preparing the “Standalone Full State“”,
page 910. Use store_program(
Mode
= 3 ) in
step 8.
(2) Make sure that eth_set_remote_tgm_format is
called in Boot Phase 1, see step 3 in
Chapter 16.7.3 ”Preparing the
“Standalone Full State“”, page 910.
(3) After each Hardware Reset, the RTC6 Ethernet
Board then boots in “Standalone Full State“ and
is then automatically set to
Remote Interface Mode.
16.9.4 Disabling
Remote Interface Mode
Temporarily
The Remote Interface Mode can be disabled
temporarily – until the next Hardware Reset.
In this state, the RTC6 Ethernet Board can be
controlled via the conventional RTC6 DLL-based
(1)
connection.
Do one of the following:
Call wrapper function
disable_remote_interface
Click the corresponding button in
RTC6conf.exe
Interrupt booting into the
“Standalone Full State“. During this time
(about 10 s with store_program(
Mode
= 3 ) in
step 8; otherwise, approx. 60 s), call
load_program_file. This aborts booting.
Afterwards, a conventional RTC6 DLL-based
connection to the RTC6 Ethernet Board can be
established.