2 Parameters
2.2 List of parameters
SINAMICS G120 Control Units CU240B-2/CU240E-2
118 List Manual (LH11), 01/2016, A5E33839529
Dependency: The setpoint for the input signals is specified using p0796.
Refer to: p0796
Note: This parameter is not saved when data is backed up (p0971).
DI: Digital Input
T: Terminal
Description: Sets the simulation mode for digital inputs.
Dependency: The setpoint for the input signals is specified using p0796.
Refer to: p0796
Note: This parameter is not saved when data is backed up (p0971).
DI: Digital Input
T: Terminal
Description: Sets the setpoint for the input signals in the digital input simulation mode.
Dependency: The simulation of a digital input is selected using p0795.
Refer to: p0795
Note: This parameter is not saved when data is backed up (p0971).
AI: Analog Input
DI: Digital Input
T: Terminal
p0795 CU digital inputs simulation mode / CU DI simulation
CU240E-2
CU240E-2_DP
CU240E-2 PN
CU240E-2_F
CU240E-2_PN_F
CU240E-2_DP_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: U, T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 2201, 2202, 2220,
2221, 2255, 2256
Min Max Factory setting
- - 0000 0000 0000 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 DI 0 (T. 5) Simulation Terminal eval -
01 DI 1 (T. 6) Simulation Terminal eval -
02 DI 2 (T. 7) Simulation Terminal eval -
03 DI 3 (T. 8) Simulation Terminal eval -
04 DI 4 (T. 16) Simulation Terminal eval -
05 DI 5 (T. 17) Simulation Terminal eval -
11 DI 11 (T. 3, 4) AI 0 Simulation Terminal eval -
12 DI 12 (T. 10, 11) AI 1 Simulation Terminal eval -
p0796 CU digital inputs simulation mode setpoint / CU DI simul setp
CU240B-2
CU240B-2_DP
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: U, T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 2201, 2202, 2220,
2221, 2255, 2256
Min Max Factory setting
- - 0000 0000 0000 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 DI 0 (T. 5) High Low -
01 DI 1 (T. 6) High Low -
02 DI 2 (T. 7) High Low -
03 DI 3 (T. 8) High Low -
11 DI 11 (T. 3, 4) AI 0 High Low -