SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
761
3 Function diagrams
3.21 Data sets
Fig. 3-180 8560 – Command Data Sets (CDS)
- 8560 -
Function diagram
87654321
fp_8560_97_51.vsd
Data sets
G120 CU240B/E-2
09.12.2015 V4.7.6
Command Data Sets (CDS)
r0836.1
r0050.1
CDS3
CDS2
CDS1
CDS0
Example:
Change over command data set
CDS0 --> CDS1
BI: p0810 = "0"
CDS0 selected
r0836.0 = 0
BI: p0810 = "1"
CDS1 selected
r0836.0 = 1
CDS0 effective
r0050.0 = 0
CDS1 effective
r0050.0 = 1
(0)
CDS select., bit 1
p0811
(722.3)
CDS select., bit 0
p0810
CDS selected
r0836
r0836
CDS effective
r0050
r0050
CDS count
2 ... 4
p0170 (2)
Source CDS
p0809[0] (0)
Start copy process
p0809[2] (0)
Target CDS
p0809[1] (1)
Data sets can only be applied and cleared when p0010 = 15 is set.